Frequently Asked Questions
Answers to common questions about product selection, technical solutions, and deployment for smart infrastructure sensing technology.
Should I choose electromagnetic or ultrasonic flow meters for urban drainage monitoring?
Full pipe = electromagnetic (±0.5%), partial pipe = radar (non-contact, maintenance-free). Consider fullness, water quality, installation, and maintenance
What are the full-scale calibration methods for Ecolor ultrasonic flowmeters and visual fusion radar level meters?
Ultrasonic flowmeter and radar level meter full-scale calibration uses standard flow methods and reference plane establishment with multi-point calibration for accuracy
What are the specific zero calibration steps for Ecolor electromagnetic flowmeters and HZ-KSLF Doppler radar flowmeters?
Zero calibration for electromagnetic and Doppler radar flowmeters requires static conditions and automatic calibration through device interface or software
What preparation work is required before commissioning Ecolor LGF electromagnetic flowmeters?
LGF electromagnetic flowmeter commissioning preparation includes installation verification, power supply check, signal grounding, medium conditions, and tool preparation
What are the common causes and solutions for unstable measurements in LGF electromagnetic flowmeters?
LGF electromagnetic flowmeter unstable measurements mainly caused by electrode contamination, interference, installation factors, solvable through cleaning, grounding, parameter adjustment
What is the correct procedure for zero-point calibration of LGF electromagnetic flowmeter?
LGF electromagnetic flowmeter zero-point calibration requires stationary medium conditions, operated through configuration software, regular calibration recommended for accuracy
How to configure RS485 Modbus communication parameters for LGF electromagnetic flowmeter?
LGF electromagnetic flowmeter supports RS485 Modbus communication, requires address and baud rate configuration, communication distance up to 1200 meters
How to properly wire the 4-20mA output signal of LGF electromagnetic flowmeter?
LGF electromagnetic flowmeter 4-20mA output requires correct positive/negative connection, attention to polarity and shielding, supports two-wire and four-wire methods
What's the difference between IP65 and IP68 protection ratings for electromagnetic flowmeters?
IP68 offers higher protection than IP65, enabling long-term underwater operation for harsh installation environments
What's the difference between accuracy class 0.5 and 0.2 in LGF electromagnetic flowmeters?
LGF electromagnetic flowmeter Class 0.2 offers higher precision than Class 0.5, with smaller error range for different application requirements
Does Ecolor Technology's electromagnetic flowmeters and RTU devices support OPC UA protocol communication integration?
Ecolor's LGF flowmeters, EC32/EC60 RTU devices fully support OPC UA protocol for standardized industrial communication integration
How to design redundant communication systems for critical water infrastructure flow monitoring to prevent data loss?
Redundant communication through dual RTU, multi-path transmission, and local buffering
What are the most reliable long-distance communication solutions for water monitoring systems over 5km?
Long-distance water monitoring uses 4G, LoRa, fiber, and microwave with redundant design
How do electromagnetic flowmeters maintain measurement accuracy in high EMI industrial environments?
EMI protection in electromagnetic flowmeters through shielding, filtering, and grounding
How to handle signal attenuation issues in ultrasonic and radar flowmeters?
Handle ultrasonic and radar flowmeter signal attenuation through positioning, parameter tuning, environmental compensation
Page 7 of 23, 341 total