Can LGF-PA66 and EC32 RTU provide solar-powered remote metering where irrigation pipelines have no mains electricity?

Most irrigation pipe metering points sit out in the fields with no mains power and no wired network.

Most irrigation pipe metering points sit out in the fields with no mains power and no wired network. The LGF-PA66 draws very little power, and together with the low-power mode of the Hero V9 EC32 RTU and a solar supply it becomes a fully off-grid remote metering terminal that reports over 4G or NB-IoT.

System layout: the solar panel charges the battery through the EC32 RTU's built-in charge controller, and the RTU samples the LGF-PA66's 4-20 mA or RS485 (Modbus RTU) signals at a set interval, uploading instantaneous and totalized flow. Size the panel and battery from local solar irradiance and the longest expected run of overcast days; for off-grid sites choose a low-power RTU such as the EC32. Keep the controller and battery in a weatherproof enclosure and use low-temperature batteries in northern winters.

Installation notes:

  • Check 4G coverage at the site first; in weak-signal areas switch to NB-IoT or fit an external antenna.
  • The LGF-PA66 sensor and converter are both IP68-rated, so the meter can live in a field valve pit — just seal the cable gland properly.
  • Accuracy matches mains-powered sites: ±0.5%(DN50-100) of reading, with the platform comparing daily totals and alarming on missing reports.

The same arrangement suits volumetric water charging, water-rights trading and irrigation fee billing — no site visits for meter reading. For more information, please visit our product page or contact our technical team.