How do I configure cross-section parameters for trapezoidal and U-shaped channels with a Doppler radar flow meter?

A Doppler radar flow meter measures surface velocity; discharge is derived from velocity multiplied

A Doppler radar flow meter measures surface velocity; discharge is derived from velocity multiplied by the wetted cross-section area. For irregular channels, the key is entering the true geometry into the device. The HZ-KSLF series supports parameterised configuration of trapezoidal, rectangular, U-shaped and compound sections.

Trapezoidal channels: enter bottom width b, side slope m (horizontal:vertical) and design depth range. The meter computes wetted area A=(b+m·h)·h in real time from the radar water level h — no manual lookup tables.

U-shaped flumes: enter the bottom radius R and the height of the vertical side walls. The HZ-KSLF has a built-in U-section algorithm that switches area formulas automatically as the level crosses from the circular segment into the straight walls.

Compound sections (main channel plus floodbanks): enter each segment separately — main-channel width, depth, bank widths and elevation offsets. When floodwater spills onto the banks the meter adds bank areas automatically. Simple devices that only model the main channel badly underestimate flood discharge; the HZ-KSLF does not.

Configuration is done via local software or remotely over 4G. Paired with an EC32 RTU, raw level, velocity and computed discharge are all reported to the platform, making it easy to sanity-check the rating behaviour.

Field tip: after configuration, run a current-meter comparison. If device discharge deviates by more than ±5%, check the entered geometry first before adjusting the velocity coefficient.